The scroll compressor is mainly used in units with a central air conditioner of more than 6p. Scroll compressors can be divided into two types: high pressure compressors and low pressure compressors. The division of the two compressors is primarily directed to the pressure level of the fully enclosed scroll compressor housing. This article will compare two compressors, hoping to help each one.


After absorbing low temperature and low pressure gaseous refrigerant from the system, the compressor directly enters the closed cavity below the scroll and then enters the scroll to compress.


The high temperature and high pressure refrigerant directly discharges the compressor from the exhaust pipe above the scroll. The entire housing is low temperature and the housing cavity (except the exhaust and exhaust chambers) is low pressure.


The high pressure chamber compressor absorbs low temperature and low pressure gas refrigerant from the system and directly enters the scroll to compress. The high temperature and high pressure refrigerant enters the closed chamber below the scroll and is then discharged from the outlet of the housing.


Turn off the main valve switch after using the air compressor every day! When the mechanical pipe is always inflated, it is easy to accelerate the aging of the air pipe, weaken the spring elasticity of the pressure switch, and directly apply the working pressure. When choosing an air compressor, pay attention to the dental chair. If the airpiece of the air compressor cannot move, it is assumed that it is too small, the air compressor choice is too small or the air consumption is too large; if it suddenly appears, the pipeline can be leaked. Some air compressors do not use an oil-free, silent series, so be sure to have a dryer. Systems that do not cause any failure contain two basic systems, compressed air systems and associated equipment (temptering machines, dental chairs, disinfection equipment, etc.). , noise, caused by vibration, can be a shelf, plus 4 shock-absorbing rubber, use a corner iron as a frame, install soundproof cotton, put the air compressor in the homemade soundproof box, remember to leave a The inlet port is like a screw air compressor, so there will be significant performance.


Anqing second-hand mobile air compressor manufacturers 02. After the permanent magnet motor is demagnetized, its working power will often exceed the rated value. Conditions that report overload or sometimes report overload only at low or high speeds are usually not caused by demagnetization. 03. The demagnetization of a permanent magnet motor requires a certain amount of time. Some months or even a year or two, if the manufacturer's choice error causes the reported current overload, it is not a motor demagnetization. Motor demagnetization cause 1. The abnormal cooling fan of the motor causes the high temperature of the motor. 2. The motor has no temperature guard assembly. 3, the ambient temperature is too high 4, motor design is not appropriate 1, cold water direct heat, intelligent control adopts a unique patented design of direct heating mode: cold water into the waste heat recovery and placement, generally can be directly heated to 52 ~ 75 °C. In the production and life, the air compressor has a huge effect in it, and the inverter air compressor occasionally has a small batch of defects. What are these loopholes caused? Today, Xiaobian and each share are divided, why the inverter air compressor has such an obstacle that the exhaust temperature is high.


The operating motor of the high pressure chamber compressor has been in a high temperature environment of 80-100 ° C. The high temperature environment has aggravated the aging of the enameled wire and the carbonization of the refrigerating oil. The motor has the characteristics of fatigue, short life and high failure rate.


The low pressure chamber compressor is a low pressure housing. The running motor is in a low temperature environment of 10 - 30 ° C, and the enameled wire is slowly aged in a low temperature environment. The refrigeration oil is not easily carbonized, and the motor is not easily fatigued. High operating efficiency, low failure rate and long life.


The housing of the high pressure chamber compressor is subjected to the high pressure of the system, while the housing of the low pressure chamber compressor is subjected to the low pressure of the system. As the power of the compressor increases, the volume also increases, and the pressure of the compressor casing also increases. Since the compressor chamber is always in a high pressure environment, a safe low pressure chamber is preferred.


The pressure limit of the cast iron housing of the high pressure chamber compressor limits the volume of the compressor. Low-pressure cavity compressors can be made even larger, while high-pressure cavity compressors can only be made smaller, so it can be made 20hp, while other high-pressure cavity brand compressors can only reach 10hp.


The high pressure cavity compressor relies on high and low pressure differentials in the compressor to supply refrigerant oil to the bearings and scrolls. However, at the beginning of the compressor start-up, the pressure difference is not enough to press the lubricating oil to the upper bearing, and it is not possible to fully refuel. Lubrication lag issues affect the life and reliability of the equipment.


In addition, the operating frequency of the high pressure cavity compressor should not be too low, otherwise the pressure difference is not sufficient for normal oil supply. Since the oil pump is forced to supply oil, the low-pressure chamber compressor can quickly supply oil to the lubrication part after starting, and is not affected by the pressure difference. The frequency can reach 20hz. It saves energy at low loads.


Anqing second-hand mobile air compressor manufacturers ordinary induction motor at low frequency operation, the speed is not stable, vibration and noise increase, the heat is added. Even the vector control method at this moment cannot completely eradicate these disadvantages. Third, energy-saving efficiency When the burden rate is only 60%, the input power of the common intake throttle control power frequency model is 38.2kw, while the permanent magnet inverter model has a shaft power of 23.6kw and a power saving rate of 37.5%. If the calculation is based on 0 hours per year, the annual electricity cost of the general asynchronous power frequency machine is 107.2 million yuan, while the annual electricity cost of the permanent magnet synchronous frequency converter is 658,000 yuan, and the annual electricity cost saved is 410 yuan. The third precaution: Correct the design. Appropriately add the thickness of the permanent magnet. From the perspective of the design of permanent magnet synchronous motor design, the relationship between armature reaction force, electromagnetic torque and permanent magnet demagnetization should be considered. Under the combined effect of the magnetic flux generated by the torque winding current and the magnetic flux generated by the radial force winding, the permanent magnet on the surface of the rotor is prone to demagnetization. In the case where the air gap of the motor is stable, the method for ensuring that the permanent magnet is not demagnetized is to appropriately increase the thickness of the permanent magnet.


In contrast to high pressure cavity compressors, the low pressure cavity compressor initially draws in refrigerant to cool the motor while the temperature of the refrigerant rises. Under similar compression conditions, the load is increased due to the increase of temperature, and the energy consumption is more natural. Therefore, the energy consumption is relatively large, and the energy efficiency ratio is relatively poor.