1. Keep the generator clean and clean at any time with a rag.

2. Before starting the generator, check the fuel; oil; cooling water: keep the zero diesel to run for 24 hours; keep the oil close to the dipstick (HI); keep the water level 50 mm under the cover of the water tank.

3. Start the battery: check the battery once each 50 hours; fill the battery with distilled water if the battery electrolyte is not 10-15 mm higher than the plate; read a number of 1.28 (25 ℃) with a hydrometer. Keep the voltage of the battery above 24 volts.

4. Oil filter: to keep the best performance, the oil filter should be repalced after running for 250 hours. Change the oil filter according to your specific running record.

5. Fuel filter: the fuel filter should be replaced after working for 250 hours.

6. Water tank: clean the water tank after working for 250 hours.

7. Air filter: remove the air filter and blown away the dust, and dry and install it after working for 250 hours; replace the air filter after working for 500 hours.

8. Oil: replace the oil after running for 250 hours. It must be better by using oil with better quality. The oil quality above CF is recommended.

9. Cooling water: change water and add antirust liquid in it after running for 250 hours.

10. V-belt: check the V-belt per 400 hours. The sink of the V-belt should be 10mm by using a 45 N force ro press the center of the loose side.Adjust if it is not. Replace all the two V-belt if there is just one belt destroyed.

11. Valve clearance: check and adjust the valve clearance per 250 hours.

12. Turbocharger: clean the turbocharger housing after running for 250 hours.

13. Fuel injector: Replace the fuel injector each 1200 hours.

14. In the repair: repair the generator set after each 3000 hours' working. The specific content contains:

a. hanging the cylinder head and clean it;

b. clean and grind the valve;

c. replace the injector;

d. check and adjust the timing of oil supply;

e. measure the offset of oil shaft;

f. determine the wear of cylinder liner.

15. Overhaul: overhaul the generator set after each 6000 hours' working. The specific content contains:

a. the content of the repair after each 3000 hours' working;

b. remove the piston, connecting rod and clean the piston; measure the piston ring groove and replace the piston ring;

c. measure the wear of crankshaft and inspect the crankshaft bearing;

d. clean the cooling system.

16. Circuit breaker, cable connection point: Remove the side plate of generater set and fasten the fixed screw of circuit breaker. Fasten the lock screw of power supply output and cable wire ear once a year.