The governor is an automatic adjusting device that automatically increases or decreases the fuel supply of the fuel injection pump according to the change of the diesel engine load, so that the diesel engine can run at a stable speed.
The governor has been widely used in industrial DC motor speed regulation, industrial conveyor speed regulation, lighting and lighting mediation, computer power supply cooling, DC fan, etc.

Main classification
According to its working principle, it can be divided into mechanical, pneumatic, hydraulic, mechanical and pneumatic composite, mechanical hydraulic composite and electronic and other forms. However, the most widely used one is the mechanical governor, which has a simple structure, reliable operation and good performance.
The hydraulic governor adds a hydraulic amplifying element (hydraulic servo) between the sensing element and the oil quantity adjusting mechanism, so that the output signal of the sensing element is transmitted to the oil quantity adjusting mechanism through the amplifying element, so it is also called indirect action type adjustment. Speeder.
post-maintenance:
1, matters needing attention
In the thunderstorm season, if the lightning protection effect of the entire workshop grid is not good, strong lightning strikes will cause the grid to be unstable, and it is prone to breakdown of the thyristor module and burnout of the fuse, which is particularly serious in the high-power DC governor. Therefore, ensuring the stability of the power supply grid is the basic condition for stable operation of DC speed regulation. If there is a strong thunderstorm or unstable grid, it is best to temporarily stop using the equipment and wait until the grid is stable before re-commissioning.
Since the start of the press is a heavy load start, the motor cannot be started frequently, and the number of times is limited to no more than 4 times per hour. When the machine is powered off, the main motor must be stopped first, and then the main motor is stopped, then the power is turned off. .
Only qualified personnel (with knowledge of the rectifier and understanding of the information provided) can perform the installation, start-up, operation, troubleshooting or repair of the rectifier. After the power supply is disconnected, the absorbing capacitor continues to carry dangerous voltage. For this reason, the rectifier must not be turned on for at least 2 minutes after the rectifier is switched off. In order to avoid arcing and the irreparable damage caused by it, the rectifier must completely protect the dust inlet. According to the pollution level, dust and foreign objects, especially those brought in by the cooling airflow, must be cleaned regularly, at least once a year. The rectifier must be cleaned with dry compressed air at a maximum pressure of 1 bar.

2, post maintenance
1) Fan replacement
The fan bearing has a design working life of 30,000 hours. In order to maintain the effectiveness of the thyristor equipment, it should be replaced in time when the service is over.
2) Replacement of printed circuit boards
Printed circuit boards contain static-sensitive components. Before touching a printed circuit board, the executive must perform an electrostatic discharge. The easiest way to do this is to touch a conductive ground conductor, such as the ground wire of the socket.
3) Replacement of thyristor module
The thyristor module is mounted by self-tapping screws. When a module is replaced, the heat sink support surface must be cleaned and a new layer of thermal paste applied to the thyristor module. Use the metric screws and fixtures of the same length to secure the module.