China Everlasting Parts Co., Ltd. is one of the most professional manufacturers and suppliers of equivalent 3 phase voltage regulator avr stamford mx321 in China. Welcome to wholesale original and genuine equivalent 3 phase voltage regulator avr stamford mx321 from our factory. Contact us for cheap products and OEM service.
Everlasting Parts is one of the leading manufacturers offering original and genuine equivalent 3 phase voltage regulator avr stamford mx321. Having specialized in this field for many years, we provide customers with the OEM products replacement. Welcome to wholesale quality, durable and cheap the aftermarket products with us.
| Automatic Voltage Regulator MX321 AVR For Stamford | ||
| Sensing Input | Voltage | 100-264 V ac maximum |
| Frequency | 50-60 Hz nominal | |
| Phase | 2 or 3 | |
| Power Input | Voltage | 170-220V ac max, 3 phase, 3 wire |
| Current | 3A/phase | |
| Frequency | 100-120 Hz nominal | |
| Output | Voltage | max 120V dc |
| Current | continuous 3.7 A (see note 1) | |
| intermittent 6A for 10 sec. | ||
| Resistance | 15 ohms minimum | |
| Regulation | +/- 0.5% RMS (see note 2) | |
| Thermal Drift | 0.02% per deg. C change in AVR ambient (see note 3) | |
| Soft Start Ramp Time | 0.4 - 4 seconds | |
| Typical system response | AVR response | 10ms |
| Filed current to 90% | 80 ms | |
| Machine Volts to 97% | 300ms | |
| External voltage adjustment | ±10% with 5k ohm 1 watt trimmer (see note 4) | |
| Under frequency protection | Set point | 95% Hz (see note 5) |
| Slope | 100-300% down to 30 Hz | |
| Max. Dwell | 20% volts/S recovery | |
| Unit power dissipation | 18 watts maximum | |
| Build up voltage | 4 Volts @ AVR terminals | |
| Analogue Input | Maximum input | ± 5 V dc (see note 6) |
| Sensitivity | 1v for 5% Generator Volts (adjustable) | |
| Input Resistance | 1k ohms | |
| Quadrature Droop Input | 10 Ohms burden | |
| Max. sensitivity: 0.22 A for 5% droop 0PF | ||
| Max. Input: 0.33 A | ||
| Current Limit Input | 10 Ohms burden | |
| Sensitivity range: 0.5-1 A | ||
| Over Voltage Detector Input | Set point: 300 V. Time delay: 1 sec (fixed) | |
| CB trip coil volts: 10-30 V dc | ||
| CB trip coil resistance: 20-60 ohms | ||
| Over Excitation Protection | Set point | 67 V dc +/-3% (fixed) |
| Time delay | 10-15 seconds (fixed) | |
| Environmental | Vibration | 20-100 Hz; 50mm/se |
| 100Hz – 2kHz; 3.3g | ||
| Operating temperature | -40 to +70°C | |
| Relative Humidity 0-70°C | 95% (see note 7) | |
| Storage temperature | -55 to +80°C | |
NOTES
1.De-rate by 20% if mounted external to generator.
2.Inclusive of 4% engine governing.
3.After 2 minutes warm-up.
4.Generator de-rate may apply. Check with factory.
5.Factory set, semi-sealed, jumper selectable.
6.De-rate output current by 5% per degree C above 60C.
7.Non condensing.